TEXT VERSION OF SLIDE:
Title: Maximum Use Concentration (MUC)
Type: Text Slide
Content:
- Must select a respirator that maintains exposure to the hazardous substance, when measured
outside the respirator, at or below the MUC
- Must not apply MUCs to conditions that are IDLH; instead must use respirators listed for IDLH
conditions per paragraph (d)(2)
- When the calculated MUC exceeds the IDLH level for a hazardous substance, or the performance
limits of the cartridge or canister, then employers must set the maximum MUC at that lower limit
- Must select a respirator appropriate for the chemical state and physical form of the
contaminant
|